版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、附录一论文原文aci structural journal technical papertitle no. 107-s61creep effects in plain and fiber-reinforced polymer-strengthened reinforced concrete beamsby m. m. reda taha, m. j. masia, k.-k. choi, p. l. shrive, and n. g. shrivethe long-term deflection behavior of two reinforced concrete (rc) beams w
2、ith similar dimensions and material properties was monitored. one beam was externally strengthened with fiberreinforced polymer (frp) strips, whereas the other was used as a control specimen. both beams have been subjected to sustained loading for over 6-1/2 years. the objective of the experiments w
3、as to assess the significance of creep in the epoxy adhesive and whether such creep might allow the frp strips to unload over time. slip movements at the ends of the frp strips were also monitored.the experimental deflections have been compared to deflection predictions using aci 209r-92 and ceb-fip
4、 mc 90. the creep deformations of the frp-strengthened beam are not as predicted from the control beam. two analytical approaches are used: a step-by-step in-time analysis and finite element (fe) modeling. both techniques demonstrate that creep of the adhesive layer can account for the differences o
5、bserved between the predicted and actual behaviors of the beams.keywords: creep; deflection; epoxy adhesive; fiber-reinforced polymer(frp); reinforced concrete.introductionin recent years there has been much research on the use of fiber-reinforced polymers (frps) to strengthen existing concrete stru
6、ctures. one popular application, used widely in practice, is to bond frp strips externally to the tension face of reinforced concrete (rc) beams to increase flexural capacity.the frp strips are typically bonded directly to the prepared concrete surface using an epoxy adhesive. the strips may be anch
7、ored mechanically near their ends or supported by additional shear reinforcement, usually in the form of u-shaped frp sheets. if the beam is subsequently loaded with sustained loads, creep in the epoxy adhesive could take place and would allow the frp strips to unload, leaving them ineffective again
8、st the sustained load. similarly, if the strips are prestressed as recently recommended by some researchers (for example, ye et al.1), creep in the epoxy may relieve some of the initial force. hence, although the frp strips can still assist in supporting additional live load, the increased sustained
9、 loads may exceed the capacity of what could effectively become the original unstrengthened beam.research into the time-dependent behavior (creep and shrinkage) of concrete beams strengthened with externally bonded frps is scarce. analytical models were verified against limited experimental observat
10、ions of rc2 and timber3 beams externally reinforced with frp strips. similar approaches were used for a composite glass fiber-reinforced polymer (gfrp) box girder with concrete in the compression flange and a carbon fiber-reinforced polymer (cfrp) strip bonded to the tension face.4 in all of the afo
11、rementioned models, however, the effect of creep in the adhesive layer bonding the frp to the tension face of the beams was neglected. that is, perfect bond and strain compatibility was assumed between the substrate and the frp. recent experiments by choi et al.5 demonstrated that significant creep
12、under shear stresses occurs in the epoxy at the concrete-frp interfaces when loading is applied within 7 days of epoxy application.herein, the results of an experimental investigation and accompanying analytical predictions of immediate and timedependent beam deflections are described. the construct
13、ion of the rc beams and the experimental program for observing their time-dependent deflection are presented. the measured deflections are compared to deflection predictions using the aci and ceb-fip methods implemented according to the recommendations of hall and ghali.6the long-term deflection dat
14、a show that the timedependent (creep) deformation of the cfrp-strengthened beam is a larger proportion of its immediate deformation than the same deformation ratio for the unstrengthened beam. the creep of the beam with the frp strips could not be predicted from the creep measured on the plain beam
15、when creep of concrete alone was considered. because cfrps have not been observed to creep at the stress levels generated,7,8 the additional creep may have occurred in the epoxy adhesive bonding the frp strips to the concrete.the creep mechanism is expected to be a simple flow of the epoxy under the
16、 shear stress,5 which develops to create tension in the frp strip. while models exist for predicting long-term deformation of rc beams strengthened with frp (for example, charkas et al.9), these models do not account explicitly for creep of epoxy adhesives. herein, we use two different approaches to
17、 determine if creep in the epoxy can account for the different behaviors observed in the beams: a step-by-step in-time analysis allowing incremental creep of concrete and epoxy in each time step and enforcing equilibrium at the end of the time step, and finite element (fe) modeling with shear flow a
18、llowed in the epoxy adhesive layer.research significancethe potential effects of creep on rc beams strengthened with externally applied frp strips are considered. it was thought that creep in the epoxy resin might relieve stress in the frp, making the frp less effective from a serviceability point o
19、f view under sustained loads. thus, frp strips used to strengthen a beam, which was then subject to increased sustained load, might end up with the extra sustained load being carried by the original concrete and steel reinforcement, not the frp. the experimental and analytical work performed reveale
20、d that the situation is more complex. nevertheless, creep deflections are greater than predicted from the creep of concrete alone, indicating contributions from creep of the epoxy. the reported experimental program was designed to identify the existence of epoxy creep rather than replicate a practic
21、al retrofit scenario. the results highlight the potential for epoxy creep to affect the long-term performance of frp retrofits in practice.experimental programtest specimens and materialstwo similar rc beams were cast from the same concrete batch (fig. 1). each beam was 3500 mm (137.8 in.) long, 280
22、 mm (11.02 in.) wide, and 180 mm (7.09 in.) high, reinforced with four longitudinal bars (canadian 10m-11.3 mm 0.445 in. diameter, 100 mm2 0.155 in.2 area) at an effective depth of 135 mm (5.31 in.) from the top surface of the beam. seven 10m stirrups were spaced uniformly in each shear span of each
23、 beam. the 28-day compressive strength of the concrete, as determined from 100 mm (4 in.) diameter, 200 mm (8 in.) high cylinderscast from the same batch of concrete as the test beamswas 34.3 2.3 mpa (4900 328 psi).fig. 1test specimens, test setup, and strain distribution.the two beams were cast tog
24、ether and storedfully supportedfor 10 months before the cfrp strips and gfrp wraps were applied. one beam (beam 1) was designated as a control specimen. two cfrp strips were bonded to the tension face of the second beam (beam 2) using an epoxy adhesive. the strips are 100 mm (3.94 in.) wide, 1.2 mm
25、(0.047 in.) thick, and 2970 mm (116.9 in.) long. over the shear spans at each end of beam 2, gfrp sheets were wrapped in a u-shape to cover the two side faces and the tension face of the beam. the cfrp strips are unidirectional with the fibers aligned along the length of the beam. the strips have a
26、modulus of elasticity of 165 gpa (23,571 ksi) and a tensile strength of 2800 mpa (400 ksi) in the direction of the fibers (manufacturers data). test setup and procedurethe beams were simply supported (pin-roller) over a span of 3200 mm (125.98 in.) (fig. 1). the midspan deflection due to self-weight
27、 was recorded using a dial gauge (least count 0.01 mm 0.000394 in.) mounted on a lightweight steel frame over the 3200 mm (125.98 in.) span. for beam 2, electronic spring gauges were mounted on the concrete adjacent to each end of one of the cfrp strips. the deflected tip of the spring gauge was car
28、efully positioned to touch the exposed end of the cfrp strip. these gauges were designed to record the longitudinal slip of the ends of the cfrp strip relative to the concrete to which the strip is bonded. each beam was then loaded in four-point bending by applying two-point loads (each 10.34 kn 2.3
29、25 kips) at a distance of 930 mm (36.61 in.) from each support. this level of loading was designed to push both beams into their working range. for beam 1, the load was expected to result in significant cracking of concrete in the tensile zone, but stresses in the concrete in compression and steel i
30、n tension would remain elastic. in beam 2, the load was expected to cause far less damage but still result in significant deflections over the long term. the loads were provided by hanging concrete blocks on load hangers bearing on the upper surface of each beam. the loads were transferred to the be
31、ams by gradually lowering the blocks onto the beams using hydraulic jacks. the hydraulic jacks were then removed. the midspan deflection of each beam relative to the self-weight value as well as the relative slip movements for the cfrp strip were recorded immediately after loading and at regular int
32、ervals thereafter. data were recorded several times during the first 24 hours of loading, daily for the first month after loading, increasing to every 3 days, weekly, biweekly and, finally, greater intervals. the loaded beams are located in the airconditioned basement level of a laboratory building
33、where the average temperature is expected to remain relatively constant with time.experimental results and discussionupon loading, the immediate midspan deflections of the beams relative to the measured self-weight deflections were 10.01 and 3.76 mm (0.394 and 0.148 in.) for the control and cfrp-str
34、engthened beams, respectively. numerous flexural cracks were observed extending from the tension face of the control beam, predominantly over the region of constant bending moment between the point loads. no flexural cracks were observed in beam 2 at first loading. such cracking would be hard to see
35、 unless significantly wide, due to the existence of the frp strips. this is because the tensile strain in the frp will be constant in the constant-moment section. if there were a few wide flexural cracks, the strain, and thus the stress, in the frp would dramatically vary between the frp still bonde
36、d to the concrete and the frp stretching across such cracks. equilibrium of the frp strip has to be maintained; therefore, rapid and large variations in force in the strip are not possible, as there is no mechanism to accommodate such stress variation. hence, the concrete in the constant-moment sect
37、ion has to crack with a large number of very thin cracks so that the strain in the frp remains constant. several months after loading, a thin flexural crack could be seen extending from the tension face of beam 2 close to the beam midspan. the cfrp strips significantly increased the cracking moment
38、capacity of beam 2. although not tested, the additional frp reinforcement was also expected to increase the ultimate moment capacity of the beam.the long-term midspan deflections (total deflection minus the initial deflection) of both beams are shown in fig. 2, plotted versus time after loading up t
39、o 2470 days of loading. the relative slip movements versus time at each end of one of the cfrp strips bonded to beam 2 are shown in fig. 3. several observations can be made:1. the long-term deflection of beam 2 is significantly less than that of beam 1. long-term deflection due to concrete creep is
40、a function of the immediate deflection, which depends on cross-sectional stiffness and cracking status. beam 1 cracked much sooner than beam 2.2. the long-term deflection of beam 2 constitutes a larger proportion of its immediate deflection compared with beam 1. plevris and triantafillou2 observed a
41、 similar response in beams externally reinforced with frp strips compared to their control specimen (no frp).3. the midspan deflection for beam 2 does not appear to be “catching” that of beam 1. that is, at first appearance, there is no indication that the cfrp reinforcement is unloading, thereby be
42、coming ineffective against the sustained load.4. the rate of increase of deflection changes with time. this is particularly evident when compared to the smooth curves of predicted long-term deflections discussed and presented in the following sections (fig. 2, 4, and 5). similar trends occur for bot
43、h beams. the periods of reduced rate of increase of deflection coincide with the summer months and those of increased creep coincide with the winter months. in the calculation of creep coefficient using ceb-fip,10 the creep coefficient reduces as the relative humidity increases, implying a reduced r
44、ate of creep during periods of higher relative humidity. the relative humidity was not recordedduring the current tests. however, relative humidity was recorded during creep tests by hall and ghali,6 conducted in the same laboratory as these tests. their results showed relative humidity varying betw
45、een 5 and 50%, with a summertime average of approximately 35% and a wintertime average of approximately 10%. the observed changes in creep rate are thus believed to be seasonal and depend on changes in relative humidity.fig. 2experimentally measured long-term midspan deflection versus time after loa
46、ding (recorded up to 2470 days) and as predicted for both beams using ceb-fip10 and aci11 models.fig. 3relative slip versus time at each end of one cfrp strip (beam 2) as measured and as predicted using fe model.5. some relative slip occurred between the concrete and cfrp strip at the strip ends soo
47、n after loading, as shown in fig. 3. since then, the movement at one end of the strip has essentially stabilized and only a relatively small gradual movement has occurred at the other end. the significant scatter in the slip readings, particularly late in the data record, is thought to result from t
48、emperature variations in the strain gauges between dates of reading (the beams are beside an air-conditioning outlet) and repeated reconnection/disconnection of the measurement instrumentation for these gauges. the maximum relative slip at the ends of the gauged cfrp strip within 2470 days was in th
49、e order of 0.17 mm (0.0067 in.)an average of approximately 60 microstrain over the length of the stripwhich implies an average loss of tensile stress of approximately 9 mpa (1285.7 psi) in the strips, and translates to an average loss of tensile force of approximately 1 kn (0.225 kips) per strip. fi
50、fty percent of this movement occurred in the first 3 weeks after loading. this observation agrees with those reported by choi et al.,confirming that the majority of epoxy creep occurs in a relatively early time period.analytical prediction of deflectionsanalytical predictions of the beam deflections
51、 were made in an attempt to identify any features of the behavior not obvious from the experimental results alone. first, the simplified procedures of ceb-fip10 and aci11 were used. these procedures focus on accurate modeling of concrete creepand thus deflectionwithout considering the effect of cree
52、p of epoxy. a step-by-step in-time analysis and an fe model were therefore developed to examine the combined effect of creep of the concrete and of the epoxy on the longterm deflection.analytical prediction of deflections using ceb-fip and aciapproaches based on the ceb-fip model code 1990 and the a
53、ci committee 209 recommendations11 were used by hall and ghali6 with the former being shown to achieve good agreement with experimental results for concrete beams reinforced with steel bars and concrete beams with gfrp bars in place of the steel bars. both approaches aim at estimating long-term defl
54、ections due to the effects of creep and shrinkage in the concrete. the methodologies are described in detail by hall and ghali6 and masia et al. fig. 4deflections predicted by step-by-step in time model versus experimentally measured deflections for beam 1 (reinforced with steel only), including eff
55、ect of concrete creep and tension stiffening of concrete ( = 0.9) and beam 2 (reinforced with steel and frp), including effects of concrete creep, tension stiffening of concrete (), and stress relaxation of frp-epoxy composite (anddays).results of analytical deflection predictions using ceb-fip10 an
56、d aci11the ceb-fip10 approach was first used to predict the immediate midspan deflections of both beams. the model predictions were calibrated against the experimental results by adjusting the cracking moment for each beam. these cracking moments are best-fit values representing the observed deflect
57、ions (immediate midspan deflection measured relative to the self-weight deflection) in the beams and not derived from the cracking strength of concrete. the cracking moments were determined in this way because the tensile strength and design shrinkage strain of the concrete, required for direct esti
58、mation of the cracking moments, were not measured in the experimental program. the cracking moments determined were used later in calculating the longterm midspan deflections for the two beams. the cracking moment capacities obtained from the calibration were 4.52 kn.m (40.08 kips.in.) and 9.12 kn.m
59、 (80.87 kips.in.), respectively, for beams 1 and 2. the large difference highlights the strengthening effects of the cfrp strips. the difference is also consistent with the observation of minor cracking for beam 2, whereas significant cracking was observed in beam 1 (note that the maximum bending mo
60、ment due to beam self-weight and applied sustained loading is 11.13 kn.m 98.69 kips.in.).the long-term midspan deflections of each of the beams were then predicted for all times after loading, at which experimental readings were recorded. the ultimate creep coefficients for concrete were adjusted to
61、 provide a leastsquares best fit between the predicted and experimental deflection values for the control beam 1. the same ultimate creep coefficients were then used to predict the long-term deflections for beam 2, assuming no creep in the adhesive bonding of the cfrp to the concrete. the use of the
62、 ultimate creep coefficients derived from beam 1 to analyze beam 2 is a valid assumption, as both beams were cast from the same concrete batch at the same time and loaded at the same environment. deflections due to shrinkage strains in the concrete were neglected. the two beams were loaded approxima
63、tely 300 days after casting, after which timeapproximately 90% of the total shrinkage strain was achieved.6 further, as the second beam was not “strengthened” until 285 days, the drying creep of the two beams was assumed to be the same. fig. 5long-term deflections at midspan of beams using fe method
64、: (a) beam 1, considering creep of concrete; and (b) beam 2, considering combined effect of creep of concrete and creep of epoxy adhesive.论文翻译普通钢筋混凝土梁和纤维增强聚合物加固的钢筋混凝土梁的徐变效应监测了两根具有相同尺寸和材料性能的rc梁的长期绕度行为。其中一根梁的外部用纤维加固材料条加固,而另一根梁是用来作为对照样本。两根梁均持续负荷超过6-1/2年。本实验的目的是评估环氧胶粘剂的蠕变的重要性,以及这样的蠕变是否允许玻璃钢条随着时间的推移有卸载荷载
65、的作用。在玻璃钢条的两端的滑移也被监测了。实验绕度已经和aci 209r-92 and ceb-fip mc 90前期预估的绕度作了对比。玻璃钢条加固梁的蠕变变形并不像从控制标本梁所预测的那样。使用了两种分析方法:一种是时程分析,另一种是有限元(fe)模型。两种分析方法表明:粘结层蠕变能解释预测和实际行为之间差异的现象。关键词:蠕变,挠度,环氧树脂粘接剂,纤维增强复合材料(玻璃钢),钢筋混凝土简介在最近几年出现了对使用(frps)纤维增强聚合物加强现有混凝土结构的大量研究。一种普及的应用,广泛使用于实践之中,那就是在普通钢筋混凝土受拉面粘结玻璃钢条以增加梁的抗弯能力。玻璃钢条通常直接用环氧胶粘
66、剂粘结于精制的混凝土表面。这些玻璃钢条可能被机械的锚固于rc梁梁端附近或者被附加抗剪钢筋支撑于梁端附近,通常采用u字型的玻璃钢条。如果随后给梁加以持续负荷,环氧胶粘剂可能发生蠕变,也允许玻璃钢条卸载,使他们不能承受持续荷载。同样,正如最近一些研究者推荐的那样,如果给玻璃钢条施加预应力,蠕变可以减弱原始的内力。因此,虽然玻璃钢条仍然可以协助承受额外的活荷载,增加的持续荷载可能超过使之成为原加固梁的能力。对(用玻璃钢条加固于混凝土梁外表面的)梁的随时间发生的行为(蠕变和收缩)的研究还很少。分析模型已被证实与用玻璃钢条加固于外表面的rc2和timber3梁的有限的实验观测相违背。类似的方法被用于混凝土箱梁在抗压凸缘的复合玻璃碳纤维增强聚合物(gfrp)与和粘结于张拉面的碳纤维增强聚合
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 窗帘合作合同范本
- 2024年度光刻机技术研发与许可合同
- 餐馆自己改造装修方案
- 餐馆消费策略研究报告
- 2024年度企业云计算数据中心建设合同
- 集装箱仓库出租合同范本
- 二零二四年度BIM模型信息管理与共享服务合同
- 铁路市场需求大数据
- 林业机械故障机理分析
- 毒笔心理分析
- 浅谈指导低年级学生朗读的几种有效方法
- 助剂化学及工艺学复习提纲应化
- CNAS-GL004:2018《标准物质_标准样品的使用指南》(2019-2-20第一次修订)
- 堤防工程监理总结报告
- 第五讲新闻评论的结构与节奏
- 护士长竞聘演讲ppt
- 进入重庆市特种设备信息化管理平台
- 意象对话放松引导词2[生活经验]
- 郦波 一生不可错过的唯美诗词
- 高速公路安全生产标准化指南1
- 学科融合课题研究实施方案
评论
0/150
提交评论